Input-Output Unit (IOU) for Secure Processing and Routing of Hull, Mechanical, & Electrical (HM&E) and Navigation Signals
AI Overview
The Navy seeks a redesigned Input-Output Unit (IOU) that consolidates signal processing for naval vessels using simplified, modular hardware instead of multiple proprietary circuit cards. This modernized approach reduces lifecycle costs while maintaining continuous operation across legacy and future shipboard systems.
This summary is AI-generated from the official solicitation.
Key Details
Official Description
IOUs are used on all Navy DDG 51 class ships to transfer Steering Control, Machinery Control, and Damage Control signals, as well as Interior Communication Alarm and Indication, Synchro and Digital Navigation data. They are also used on USN LHA(R) class ships, in Aegis Ashore facilities, and across a variety of Foreign Military Sales (FMS) cases. IOUs serve as a translation point when sending and receiving non-Ethernet traffic, such as synchro and low-level serial data, to Ethernet user systems....
Change History
Material change · Requirements + Scope + Description
Input-Output Unit (IOU) for Secure Processing and Routing of Hull, Mechanical, & Electrical (HM&E) and Navigation Signals
- Q1 answered (previously "Response Pending" in substance): The IOU internal AC-to-DC power supply is to be sized only for MIL-STD-1399-300 Type I (115/120 V, 60 Hz) primary power across the two shipboard lighting circuits. Type II (400 Hz) is not a primary power input; it is required only as a separate, isolated synchro reference input. That reference input must still meet Type II steady-state and transient tolerances so 400 Hz disturbances don't degrade synchro accuracy or damage I/O circuitry.
- Why it matters: Applicants should not design the power supply to accept 400 Hz as a primary input. Concept designs need a separate isolated 400 Hz synchro reference path, with compliance to Type II tolerances.
- Q2 unchanged: The answer on 24-channel capacity (16 existing channels plus 50% growth, 600 W maximum, higher-density IOMs) and the promise of a baseline attachment is the same as before.
Material change · Requirements + Scope + Description
Input-Output Unit (IOU) for Secure Processing and Routing of Hull, Mechanical, & Electrical (HM&E) and Navigation Signals
- New Q1 added on IOU power: the topic asks whether the Phase I concept must size the IOU power supply to accept Type II (400 Hz) power as a primary input in addition to Type I, or whether 400 Hz is needed only as a separately supplied synchro reference. The question cites MIL-STD-1399-300 compliance and connection to two independent 120 V, 60 Hz shipboard lighting circuits. No answer is shown yet, so this is an open point.
- Former Q1 renumbered to Q2 (required interface capacity). Its question and answer text are unchanged: 16 existing channels, a 24-channel target with 50% growth, a 600W maximum power limit, and Type I interface baseline data to be provided to awardees as an attachment.
Why it matters: applicants should plan for a possible dual-frequency power requirement (Type I and Type II) until the Government answers the new question, since it affects power supply design, size, and cost. Watch for an answer to the new Q1 before finalizing the concept.
Informational change · Status
Input-Output Unit (IOU) for Secure Processing and Routing of Hull, Mechanical, & Electrical (HM&E) and Navigation Signals
The solicitation status moved from Pre-Release to Open. Applicants can now submit proposals through the normal submission channels, so preparation that was on hold during pre-release can move into active drafting. Check the posted close date and submission instructions right away, since the open window is what sets your deadline. Pre-release materials that were only forecasts should now be replaced with the final solicitation text, and any requirements you planned around should be verified against the open version.
Material change · Requirements + Attachment + Scope + Description
Input-Output Unit (IOU) for Secure Processing and Routing of Hull, Mechanical, & Electrical (HM&E) and Navigation Signals
A1 was added to the existing Q1 (required interface capacity), which was previously unanswered or pending. Key clarifications:
- Growth target defined: The 50% growth requirement means supporting 24 channels, up from the existing design's 16 channels.
- Footprint and power constraints: Use higher-density I/O modules to stay within the existing shipboard footprint as much as possible; the concept must accommodate 24 channels of any signal type, or a mix, within a 600 W maximum power limit.
- Standards governing interfaces: Lower-level processing and all interfaces must follow the cited military and commercial standards (IEEE, RFC, MIL-STD-XXXX, etc.).
- Detailed baseline data deferred: Channel counts, signal ranges, data rates, and timing requirements for Type I interfaces (DC analog, synchro, NTDS, STANAG, Ethernet) will be provided as an attachment to awardees only, so bidders should plan for that information arriving after award.
Why it matters: applicants can now size their design to a concrete 24-channel, 600 W target, but cannot finalize interface details until the awardee attachment is released.
Material change · Requirements + Description
Input-Output Unit (IOU) for Secure Processing and Routing of Hull, Mechanical, & Electrical (HM&E) and Navigation Signals
- Q&A added (Q1, interface capacity): A new question asks whether the performer must define the number of connections for each required signal type and provide at least 50% additional growth capacity, or whether the Government has an existing baseline connection count the prototype must support.
- Why it matters: Applicants should note that the answer is not yet provided in this version. Until the Government responds, the scope of required interface capacity is unclear, which affects hardware sizing, cost estimates, and the technical approach. Teams planning to bid should prepare a proposal assumption and watch for the response, since a fixed baseline would limit flexibility while an open definition would require them to justify their own connection counts and growth margin.
Input-Output Unit (IOU) for Secure Processing and Routing of Hull, Mechanical, & Electrical (HM&E) and Navigation Signals
New opportunity: Input-Output Unit (IOU) for Secure Processing and Routing of Hull, Mechanical, & Electrical (HM&E) and Navigation Signals
Similar Opportunities
Get Alerts for Opportunities Like This
RallyProp monitors 17 funding and innovation sources and sends instant alerts when opportunities match your technology and capabilities.
Build Your Free Lane