Expeditionary Water Quality Sensors
AI Overview
Navy seeks rapid, field-ready water quality sensors that let small units verify expeditionary purified water meets military potability standards without lab support or chemical reagents. The goal is testing in under 15 minutes for key parameters and detection of microbial threats within an hour, reducing reliance on vulnerable resupply.
This summary is AI-generated from the official solicitation.
Key Details
Official Description
Expeditionary forces need updated water testing capabilities to support operations in austere, contested environments. Without proper water testing, water purified in the field are not certified potable for consumption. This creates an unacceptable logistics burden to transport water, or a health risks when consuming untested water; hindering the self-sufficiency, readiness, and lethality required for operations against a pacing challenge. Current approved state-of-the-art water quality testing ...
Change History
Material change · Requirements + Description + Attachment
Expeditionary Water Quality Sensors
- New Q&A added: A new Q1 asks for the current authoritative version of TB MED 577. The answer states it is the 1 May 2010 version, recertified 18 Dec 2017, which supersedes the 2005 link in Reference 2. Applicants should use this version for their technical baseline.
- Renumbering only: The prior Q1 (external data links) and Q2 (kit procurement) are now Q2 and Q3 with unchanged text and answers. The data-link answer still confirms that systems operating natively offline, with optional export when secure networks permit, are acceptable, and that sole reliance on network connections is not.
- Why it matters: Applicants should confirm their proposed architecture against the TB MED 577 2017 recertification, not the 2005 reference. The procurement answer still indicates WQAS-P technical data is Distribution Statement D (CUI), available only to awardees with a need-to-know after contract award.
Informational change · Description + Requirements
Expeditionary Water Quality Sensors
- A new question was added (Q1) asking whether the "without external laboratory support" requirement bars external data links such as STARSHIELD, and whether remotely hosted algorithms for detecting pathogens, chemical warfare agents, and radiological threats would meet the Phase I objectives. It also asks whether all analytics must run locally on-island with Marines, independent of external networks.
- The previously existing question on procuring TB-MED-577 water evaluation kits was renumbered from Q1 to Q2. Its answer is unchanged: WQAS-P technical documentation is Distribution Statement D CUI, available only to DoD and DoD contractors with need-to-know after award, and baseline kits are identified by NSNs or established defense vendors.
Why it matters: applicants proposing cloud-hosted or networked sensing should note that the Government's answer to the new question is still pending, so the connectivity assumption is unresolved. Until a response is posted, a design relying on external data links carries compliance risk.
Informational change · Description
Expeditionary Water Quality Sensors
The Q&A section gained its first answer. Q1 (how commercial companies can procure the water evaluation kits in TB-MED-577) was previously unanswered and now has a response:
- The test equipment and procedures are referenced in military technical publications, specifically the Water Quality Analyzer Set-Purification (WQAS-P) documentation.
- The WQAS-P technical manuals and related system documents are marked Distribution Statement D (DoD and DoD contractors only) as Controlled Unclassified Information, so they are not publicly available.
- Access to Distribution Statement D data is generally granted through the contracting authority to awardees with a demonstrated need-to-know, once under contract.
- The government does not endorse specific commercial vendors, but baseline kits are standard military inventory items identifiable by National Stock Numbers (NSNs) or through established defense suppliers of military water-testing systems.
Why it matters: Applicants who lack a contract cannot obtain the WQAS-P documentation directly, so pre-award technical preparation is limited. Firms should plan to request the data after award, and should identify NSNs and defense suppliers early to assess sourcing of baseline kits.
Informational change · Description
Expeditionary Water Quality Sensors
The Q&A section now contains one question: "How can commercial companies procure the water evaluation kits in TB-MED-577?" No answer is shown in the updated version, so applicants should treat the question as posted but unresolved. Commercial firms interested in supplying these kits should watch for the government's response, since it will likely clarify whether direct procurement or a specific acquisition route applies to them.
Expeditionary Water Quality Sensors
New opportunity: Expeditionary Water Quality Sensors
Similar Opportunities
Lightweight, Energy-Efficient Portable Nitrogen Generator for Expeditionary Operations
Due January 6, 2027
Pre-ReleasePersistent, Geochemically-Driven Low-Temperature Power Systems for Subsea Intelligence, Surveillance, and Reconnaissance
Due January 6, 2027
ActiveCommand Wide Broad Agency Announcement for Naval Facilities Engineering and Expeditionary Warfare Center (NAVFAC EXWC) Research, Development, Testing, and Evaluation
Due June 14, 2027
Get Alerts for Opportunities Like This
RallyProp monitors 17 funding and innovation sources and sends instant alerts when opportunities match your technology and capabilities.
Build Your Free Lane