High Speed, Low Temperature Hyperspectral Imager for High Enthalpy Ground Testing
AI Overview
AEDC seeks a high-speed hyperspectral imaging system to simultaneously measure surface temperature and emissivity on test articles during ground testing. The solution must achieve 4000 Hz capture rates across 0-1500°F with submillimeter spatial resolution and ±10°F accuracy.
This summary is AI-generated from the official solicitation.
Key Details
Official Description
AEDC requires a method to resolve temperature and emissivity across the surface of test articles. Specifically, there is a need for a high-speed low-temperature measurement solution that overlaps with other higher-temperature capabilities. The solution threshold requirements are to measure surface temperature from 0-1500 F (2000 F objective), at 4000 Hz (5000 Hz objective), with a pixel footprint of at most 0.1 inch (0.05 inch objective) and an accuracy of +/- 10 deg F (+/- 5 deg F objective).
Change History
Informational change · Description + Requirements
High Speed, Low Temperature Hyperspectral Imager for High Enthalpy Ground Testing
- Answers added to previously pending questions: Q1 (accuracy definition and scope) now has answers covering 0 °F vs room-temperature lower bound, ±10 °F/±5 °F defined as 95% confidence (2-sigma), per-pixel application with no averaging that degrades footprint or sampling rate, representative opaque TPS material classes, path-emission bounding assumptions, external pre-test calibration allowed, 50 lbm sensor head weight, no prescribed validation procedure, no atmospheric-pressure viewport tests, no heating lasers, and the 0.1 in. footprint applying out to 10 ft.
- Q2 answered: Opaque TPS materials are the primary requirement, with flat and curved geometries and smooth-to-rough dynamic surfaces. Haze/scattering for IR-transmitting articles is not a baseline requirement and no datasets are provided.
- Q3 and Q4 answered (partially shown): Multiband approaches are acceptable if they resolve temperature and changing emissivity; the minimum object size is not disclosed, and the field of view is set by a 32 × 32 window at 4,000 Hz with 256 × 256 at 60 Hz. Working distance is 1.5 to 10 ft, and the facility port and arch dimensions are withheld pending an Interface Control Document for selected awardees.
Why it matters: Applicants can now size the accuracy, footprint, and weight specifications directly, though the 256 × 256 mode and mounting dimensions still depend on the ICD.
Informational change · Description + Requirements
High Speed, Low Temperature Hyperspectral Imager for High Enthalpy Ground Testing
- New questions added (Q1, Q2, Q3-Q4 reorganized): Q1 now asks about ±10 °F accuracy at 4,000 Hz down to 0 °F, whether thresholds are max error, RMS, or confidence-level uncertainty, and whether averaging is allowed. Other new Q1 topics cover representative test-material classes and emissivity databases, viewport-path conditions (gas, particulates, ionized gas, background reflection), calibration source locations, packaging, environmental conditions, Phase II verification methods, laser wavelengths, and per-pixel footprint distance at 10 ft.
- New Q2 on test-article characteristics: asks whether the instrument must handle opaque, semitransparent, or transparent articles, flat or curved and smooth or rough surfaces, and haze or internal scattering that may change during ablation.
- Previously answered questions carried forward: the minimum spectral band question (multiband acceptable, ±10 °F/±5 °F and 4,000/5,000 Hz thresholds), the 32 × 32 and 256 × 256 pixel windows, the 0.1 in./0.05 in. pixel footprint definition, the 1.5 to 10 ft working distance, the indoor atmospheric and sub-atmospheric port configurations, and the 50 lbm sensor head preference all appear again with no visible new answer text.
- Why it matters: the new questions signal likely requirements for low-temperature accuracy, vacuum-port optics, and laser-protection filtering that were not stated before. Applicants should watch for answers to these, since many remain unanswered in this version.
Informational change · Description
High Speed, Low Temperature Hyperspectral Imager for High Enthalpy Ground Testing
- New Q&A added (Q1): Two new questions were added on spectral approach: (1) whether a minimum number of spectral bands is required for hyperspectral status, or whether a multiband approach is acceptable; (2) the minimum object size in inches for a single image acquisition.
- Answer to new Q1 clarifies: No minimum number of spectral bands is prescribed. AEDC will accept a multiband/multispectral or alternative optical approach if it dynamically resolves temperature and changing emissivity within ±10 °F (±5 °F objective) at 4,000 Hz (5,000 Hz objective), with relaxed emissivity update rates allowed at the highest sampling frequencies.
- Answer to new Q2 on object size: Minimum spatial coverage is defined by the pixel array format and the ≤0.1 in. pixel footprint, not a fixed object dimension. A 32×32 window at 4,000–5,000 Hz on a region of interest is sufficient, with 256×256 desired at 60 Hz. No specific test article dimensions were disclosed.
- Existing Q&A reorganized: The earlier questions on pixel footprint, working distance, environmental protection, and physical space were renumbered under a new Q2, and the answer labels were updated. The answers themselves are unchanged.
Why it matters: Applicants no longer need a hyperspectral system to qualify; a multiband design is explicitly acceptable if it meets the temperature, emissivity, and sampling thresholds. The object-size question is answered by pixel-window specifications rather than a dimension, so proposals should be sized around the 32×32 and 256×256 targets.
Informational change · Requirements + Description
High Speed, Low Temperature Hyperspectral Imager for High Enthalpy Ground Testing
The Q&A section gained four new answers, all addressing previously open questions:
- Pixel footprint (Q1): Defined as the projected size of each pixel on the test article surface, not an MTF or subpixel resolvable-feature limit. Threshold is 0.1 in. × 0.1 in. (objective 0.05 in. × 0.05 in.).
- Working distance and field of view (Q2): Working distances of roughly 1.5 to 10 ft. Field of view is a 32 × 32 pixel window at 4,000 Hz (objective 5,000 Hz), with a desired 256 × 256 pixel mode at 60 Hz. Specific test article dimensions were not disclosed.
- Environment and protection (Q3): Indoor, room-temperature, ~1 atm lab for two atmospheric units; one sub-atmospheric unit mounted outside a quartz or sapphire viewport. Protection is external (fore-optics or enclosures) for atmospheric units.
- Physical space (Q4): Viewport and camera arch dimensions withheld; an Interface Control Document is available to selected awardees. Desired sensor head weight is 50 lbm or less, with a compact remote head preferred.
Why it matters: the Q&A moved from open questions to answers, so applicants can now size the sensor head, optics, and enclosure. Note that the 50 lbm limit and the 60 Hz, 256 × 256 mode are design targets. Teams that need exact port geometry should request the ICD.
Informational change · Description
High Speed, Low Temperature Hyperspectral Imager for High Enthalpy Ground Testing
- Q&A added (previous version empty): The Q&A section now contains a single question with several sub-parts, all asking for technical clarification on an imaging system.
- Topics raised:
- Physical meaning of "pixel footprint" (sampling versus effective spatial resolution, composite pixel pitch).
- Object working distance and field of view, or maximum size of the object under test.
- Whether the imaging system needs protection from the test environment, and whether that protection is external (with optical-pathway component specs) or integrated (with camera-port environment details).
- Available physical space, including camera port diameter and the shape and size of the envelope available to the system.
- No answers are provided yet in this version, so no eligibility, budget, timeline, security, data-rights, or submission rules are clarified by this change.
Why it matters: Applicants planning imaging-system proposals should note that key design parameters (resolution definition, working distance, field of view, environmental protection, and packaging constraints) are still open questions. Teams should watch for the agency's responses, since these answers will likely drive the optical design, enclosure approach, and cost estimates in any proposal.
Informational change · Status
High Speed, Low Temperature Hyperspectral Imager for High Enthalpy Ground Testing
The solicitation status moved from Pre-Release to Open. Applicants can now submit proposals (or begin the formal application process) rather than only monitor for the release. Practically, this means you should review the full solicitation documents now, confirm eligibility, note the official close date and submission portal, and start preparing your application and any required registrations, since the window for questions and submissions is active.
High Speed, Low Temperature Hyperspectral Imager for High Enthalpy Ground Testing
New opportunity: High Speed, Low Temperature Hyperspectral Imager for High Enthalpy Ground Testing
Similar Opportunities
Luminescence-Based Surface Measurement Technique for Simultaneous Pressure and Temperature Measurements within Non-Oxygen Based Hypersonic Ground Test Facilities
Due November 25, 2026
ActiveReusable Illumination System
Due November 25, 2026
Pre-ReleaseInnovative Shortwave Infrared High Energy Laser Source and Coupled Imager
Due January 6, 2027
Get Alerts for Opportunities Like This
RallyProp monitors 17 funding and innovation sources and sends instant alerts when opportunities match your technology and capabilities.
Build Your Free Lane