--- Attachment text --- [RFC_038___Answered.docx] REQUEST FOR SPECIFICATION CLARIFICATION #038
Work Item: 513
Paragraph/Section: 7.0
Title: Sewage/ Macerator Pump Overhaul
Question:
OEM states that the work item is not applicable to any of the hulls after #12, and only 524A is required. Please advise on how to proceed.
Answer:
KTR shall bid the scope of work as written. OEM can advise on site if work is to be de-scoped
[RFC_039_043___Answered.docx] REQUEST FOR SPECIFICATION CLARIFICATIO...
Change History
Informational change · Description
USNS POINT LOMA (T-EPF 15) Mid-Term Availability
Key Changes to N3220526R6128 Amendment 0002
The description now includes 16 additional Requests for Clarification (RFCs 038-052) addressing specific work scope questions:
Major Clarifications:
- WI 513 (Sewage/Macerator Pump): Contractors must bid scope as written; OEM exceptions handled on-site
- WI 120 (Aluminum Repairs): Clarified furnished plate quantities (4 sheets of 6mm 5083, 8 sheets of 8mm 5083, 4 sheets of 6mm 6061); crack repairs may involve dissimilar aluminum grades (5xxx/6xxx/5454) with varying thicknesses
- WI 160 (Watertight Closures): Reference drawing shows 76 openings (not 69); overlaps with WI 1003
- WI 201 (Plate Cooler): SmartPAC coolers must be cleaned; in-place fittings allow optional disassembly per Port Engineer discretion
- WI 173A (Preserve and Paint Topside): Use version dated 2026-09-12 from MSC contracting
- Cast Aluminum/Duplex Steel: No projected repairs; changes via future contract modification if needed
- Staging Requirements: Minimal 4-meter staging needed; refer to HSSD document for specific locations
Impact: Contractors must bid full scope uncertainty on material grades, thicknesses, and inspection-dependent staging rather than exact specifications.
Informational change · Description
USNS POINT LOMA (T-EPF 15) Mid-Term Availability
Description information changed.
Material change · Requirements + Scope + Description
USNS POINT LOMA (T-EPF 15) Mid-Term Availability
Multiple Request for Clarification responses added critical technical specifications, work item clarifications, and contract details (AGR/ODC costs, shore power duration, equipment serials, work item scope) that materially affect bidding and performance requirements.
USNS POINT LOMA (T-EPF 15) Mid-Term Availability
New opportunity: USNS POINT LOMA (T-EPF 15) Mid-Term Availability
Similar Opportunities
Get Alerts for Opportunities Like This
RallyProp monitors thousands of funding sources and sends instant alerts when opportunities match your technology and capabilities.
Start Free Trial